Type of Filter required Cartridge Filter Fluid Handled Gas Application Post Filter to Blower Reactivated Dryer Flow rate (min.) kg/hr 118790 Flow rate (normal) kg/hr 130670 Flow rate (Max) kg/hr 180946 Inlet Pressure kg/cm2 (a) 28.1 Inlet Temperature Deg C 4 to 250 Particles to be removed Size of the particles to be removed Micron 3 Microns & larger Allowable pressure drop (clean) kg/cm2 0.1 Allowable pressure drop (Dirty) kg/cm2 0.2 Filtration Efficiency Remove 99% of all particles of 3 microns and larger Fluid Properties @ op. pressure & temp Density kg/m3 12.65 Viscosity cP 0.0145 Presence of Corrosive components No Mechanical Data Design Pressure kg/cm2 g 29.8 Design Temperature Deg C 250 Material of construction Body KCS+PWHT Filter Element SS 316 Mesh, Double open end with Welded end caps Filter Element Model ** Filter Element Size 40"L x 76 mm Dia Total Gross Filtering Area per Element sq. meter 0.24 No. of Filter elements /housing nos. 46 Filter Element Burst Pressure kg/cm2 5 Dirt Holding Capacity Please specify Filter Element Collapsible Pressure kg/cm2 Please specify Corrosion Allowance- Body mm 1.6 Corrosion Allowance- Element mm 0 Inlet/ outlet Size 16" NB, 300# Total no. of cartridges required for this project 400 nos
Note: 1. Filter to be subjected to steam out conditions of 0.5 kg/cm2 and 200 Deg C