Urgent Requirement Of Optical Fibre Sm G652 B [India] |
THE SPECIFICATIONS ARE AS PER BELOW, IF OUR SPECIFICATIONS ARE MATCHING WITH YOR PRODUCT, YOUR ARE REQUESTED TO SEND THE QUOTATION AS EARLY AS POSSIBLE.
KINDLY RESPOND TO FOLLOWING MAIL ID,
REGARDS, NISHANT D BORSE DY MGR - STRATEGIC SOURCING Usha Martin Cables Ltd. India mobile - +91 9723816655
RAW MATERIAL SPECIFICATION FOR OPTICAL FIBER-SM
1.
REFERENCE: TEC specification
2.
SCOPE: This specification covers the requirements of optical fiber used for manufacturing of Optical Fibre Cables. Optical fiber, the main raw material in cable manufacturing is used for the data transmission medium.
3.
GENERAL: The optical fiber shall confirm to the specification given below.
4.
SPECIFICATIONS:
S.No.
Parameters
Values Required G652
Unit
1
Attenuation at 1310 nm
< 0.350
dB/km
2
Attenuation at 1550 nm
< 0.210
dB/km
3
Attenuation at 1625 nm
-
dB/km
4
Attenuation at 1285-1310nm
< 0.350 + 0.2
dB/km
5
Point Discontinuity
< 0.1
dB
6
Cutoff wavelength
1160 - 1310
nm
7
PMD at 1310 and 1550 nm
< 0.2
ps/sqrt(km)
8
Dispersion at 1285-1330 nm
< 3.5
ps/nm*km
9
Dispersion at 1270-1340 nm
< 5.3
ps/nm*km
10
Dispersion at 1550 nm
< 18
ps/nm*km
11
Dispersion Slope
< 0.092
ps/nm2*km
12
Zero Dispersion Wavelength
1300-1320
nm
13
Mode field Diameter @ 1310 nm
8.8-9.8
micron
14
Mode field Diameter @ 1550 nm
-
micron
15
Mode field Concentricity error
< 0.8
micron
16
Coating Cladding Concentricity
-
microns
17
Clad Diameter
124.0-126.0
micron
18
Clad non circularity
< 1
%
19
Coat Diameter
245 � 10
micron
20
Fiber bend test @ 100 turns 30�1.0 mm radius mandrel
< 0.1 at 1550 nm
dB
21
Fiber bend test @ 1 turn 32 mm diameter mandrel
< 0.5
dB
22
Dynamic Tensile Strength - Unaged
> 550
Kpsi
23
Dynamic Tensile Strength- Aged
> 440
Kpsi
24
Dynamic Fatigue
> 20
-
25
Static Fatigue
> 20
-
26
Stripping Force (for removal of 30 mm coating)
1.3-8.9
Newton
27
Fiber curl (Radius of curvature)
> 4
Meter
28
Proof test level (min)
1
%
5.
PACKING AND MARKING: The material shall be supplied in unsplice lengths in multiple of 2.1/2.2 Kms (i.e 10.5/12.6/25.2/50.4) or as per P.O , in plastic spools of dimensions:
Flange Diameter 240 mm +/- 10 %
Barrel diameter 150 mm +/- 10 %
Traverse diameter 100 mm +/- 10 % & 210 mm � 10 %
Overall diameter 110 mm +/- 10 % & 220 mm � 10 %
Bore Diameter 25.4 mm +/- 2 %
The material shall be packed in dust and moisture free packing., preferably with a plastic case. The packing should be good enough to withstand the rough handling during transportation. Temperature variation during transportation should not degrade the optical fiber properties. Each test report should have the following information
Manufacturers Name
Material Grade
Batch Number
PO Number
Each of the fiber spool shall has the following marking
Manufacturers Name
Material Grade
Spool ID
Length of the fiber
Attenuation at 1310 and 1550 nm
6.
CRITERIA FOR ACCEPTANCE: The supplies complying with the above conditions and yielding satisfactory results in processing shall be accepted. The Supplier will provide the CACT source approval certificate.
7. TEST CERTIFICATES: Supplier will furnish test certificates (Hard copy and an 3 � Floppy or Soft Copy) with each consignment certifying the conformity of all the parameters as per specifications & Group Refractive Index. |
|
|